Self-Support Aerial Installation Cable With FRP Rods (Flat) KC-OKGO
Usage:
For suspension between communication poles, for installation in cable racks, on the walls of building in case of absence risks of mechanical damages, in protection pipes by blowing method.





Structure
Specifications
Documents

Outer sheath
Optical loose tube
Optical fiber
Peripheral strength element
Code of cable type | 1209 | 1210 | 1221 | 1222 | 1223 | 1224 | |
Number of fibers | 12 | 24 | 2 | 4 | 16 | 24 | |
Number of loose tube | 1 | 2 | 1 | ||||
Number of fibers in loose tube | 2-12 | 12-24 | 1-2 | 2-4 | 8-16 | 24 | |
Short-term crush test, kN/cm (N/10cm) | 1,0 (10000) | ||||||
Dynamic tensile strength, not less than, kN | 1,7 | 0,6 | 1,1 | 1,5 | 1,9 | ||
Operating temperature, °С | – 40…+60 °С | – 50…+70 °С | |||||
Installation temperature, °С | – 10…+50 °С | ||||||
Overall dimensions, thickness x height, mm | 3,6х8,1 | 3,6х11,0 | 5,3х2,4 | 6,5х2,8 | 7,2х3,6 | 7,7х4,0 |