Cable terminations rek-1H-FU, rek-1H-А-FU, rek-1H-S-FU

Cable terminations rek-1H-FU, rek-1H-А-FU, rek-1H-S-FU for control cables with PVC insulation.

Technical performance

Terminations are used for terminating control cables with PVC insulation (rek-1H), shielded (rek-1H-S) and armored with steel tapes (rek-1H-A) for a voltage of 0.6/1kV.

Termination set includes:

  1. Spade lugs manufactured by GPH;
  2. Special tapes;
  3. Heat-shrinkable tube with an adhesive layer;
  4. Grounding kit for metal cable parts (for rek-1H-S-FU and rek-1H-A-FU sets);
  5. Installation instructions.

Termination design

The conductors are terminated with insulated crimping lugs. To prevent moisture from entering the lug, water-repellent mastic is used. The space between the conductors is filled with water-repellent mastic.

The cable sheath end is sealed with mastic tape. For mechanical protection, a heat-shrinkable tube with an adhesive underlayer is used to provide additional sealing.

Grounding of the metal parts of the cable (for the rek-1H-S-FU and rek-1H-A-FU sets) is carried out by solderless method using spring rings.

Application
rek-1H-FU termination is designed to terminate control cables with polyethylene or PVC insulation without armor.
Cable type:
KVVG, AKVVG, KPGV, AKPVG, KPsVG, AKPsVB, etc.

Application
rek-1H-S-FU termination is designed to terminate shielded control cables with polyethylene or PVC insulation without armor.
Cable type
KVVG, AKVVG, KPsVG, AKPsVGE, etc.

Application
rek-1H-A-FU termination is designed to terminate control cables with polyethylene or PVC insulation with tape armor.
Cable type
AKVVB, KVVBG, AKVVBbG, KVBbShv, KPVBG, AKPBbShv, etc.

TABLE FOR ORDERING REK-1H-FU TERMINATIONS

Rated voltage, kV Number of conductors in cable Conductor cross-section, mm2 Ordering designation
rek-1H-FU rek-1H-S-FU  rek-1H-A-FU
0,6/1
4
0,75-1,5
1,5-2,5
4-6
rek-1H-4-(conductor section)-FU rek-1H-4-(conductor section)-S-FU rek-1H-4-(conductor section)-A-FU
5
rek-1H-5-(conductor section)-FU rek-1H-5-(conductor section)- S-FU rek-1H-5-(conductor section)- A-FU
7
rek-1H-7-(conductor section)-FU rek-1H-7-(conductor section)- S-FU rek-1H-7-(conductor section)- A-FU
10
rek-1H-10-(conductor section)-FU rek-1H-10-(conductor section)- S-FU rek-1H-10-(conductor section)- A-FU
14
rek-1H-14-(conductor section)-FU rek-1H-14-(conductor section)- S-FU rek-1H-14-(conductor section)- A-FU
19
rek-1H-19-(conductor section)-FU rek-1H-19-(conductor section)- S-FU rek-1H-19-(conductor section)- A-FU
27
rek-1H-27-(conductor section)-FU rek-1H-27-(conductor section)- S-FU rek-1H-27-(conductor section)- A-FU
37
rek-1H-37-(conductor section)-FU rek-1H-37-(conductor section)- S-FU rek-1H-37-(conductor section)- A-FU
52
rek-1H-52-(conductor section)-FU rek-1H-52-(conductor section)- S-FU rek-1H-52-(conductor section)- A-FU
61
rek-1H-61-(conductor section)-FU rek-1H-61-(conductor section)- S-FU rek-1H-61-(conductor section)- A-FU

Order